KBE1JA KBE1S KBE5S KBE5L 2-Step

Temperature diagram







EXCELLENCE REBORN
New features of a new VAL6 KBE5L
NEW 2-step output control
COMPARISON DIAGRAM FOR TEMPERATURE DISTRIBUTION
ENERGY SAVING
Selecting a low combustion can make fuel consumption lower. This means that this heater can save our operation cost. For example, in early winter if the heater operates with a low combustion, it can save 1.2 gallons a day, 24 gallons a month.
NEW 2-step output control
As ambient temperature decreases, viscosity increases, to counterbalance this effect, a heater is built into the fuel line to keep the fuel moving smoothly.
Specification

KBE1JA KBE1S KBE5S KBE5L 2-step
HEAT OUTPUT 34,500kcal
28,000kcal
111,000BTU/h
High: 118,000BTU/h
Low: 100,000BTU/h
(40kW) (32.5kW) (32.5kW) (Low: 29kW/High: 35kW)
FUEL Kerosene, #1 Diesel Kerosene, #1 Diesel Kerosene, #1 Diesel Kerosene, #1 Diesel
TANK CAPACITY 57LITERS 35LITERS 9.2 gallons 15 gallons
POWER SOURCE 230V/50Hz
120V/60Hz
230V/50Hz 120V/60Hz 120V/60Hz
POWER CONSUMPTION 65W 60W 80W 120W
CONTROL SYSTEM 5SEC. PREPURGE
5SEC. PREPURGE
5SEC. PREPURGE
5SEC. PREPURGE
180SEC. POSTPURGE 180SEC. POSTPURGE 180SEC. POSTPURGE 180SEC. POSTPURGE
SAFTY DEVICE PHOTOCELL FLAME MONITOR
1.6A FUSE
PHOTOCELL FLAME
MONITOR
1.6A FUSE
PHOTOCELL FLAME
MONITOR
3A FUSE
PHOTOCELL FLAME
MONITOR
3A FUSE
FUEL CONSUMPTION 3.8 l/h 3.21 l/h 0.85gal/h High: 0.9gal/h
Low: 0.75gal/h
EXTERNAL DIMENSION
(HXWXD)
925X660X955(mm) 810X655X695(mm) 36.2X27.9X27.4(in) 40.2X28.0X27.4(in)
DRY WEIGHT 53kg 38kg 83.8lbs 92.6lbs
ACCESSORY N/A THERMOSTAT
TERMINALS
THERMOSTAT
TERMINALS
THERMOSTAT TERMINALS
FUEL PRE-HEATER
Specifications are subject to change without notice.