| KBE1JA |
KBE1S |
KBE5S |
KBE5L 2-Step |
Temperature diagram



|
|
ENERGY SAVING
Selecting a low combustion can make fuel consumption lower. This means that this heater can save our operation cost. For example, in early winter if the heater operates with a low combustion, it can save 1.2 gallons a day, 24 gallons a month.
 As ambient temperature decreases, viscosity increases, to counterbalance this effect, a heater is built into the fuel line to keep the fuel moving smoothly.
|
|
| Specification |
|
KBE1JA |
KBE1S |
KBE5S |
KBE5L 2-step |
| HEAT OUTPUT |
34,500kcal
|
28,000kcal
|
111,000BTU/h
|
High: 118,000BTU/h
Low: 100,000BTU/h |
|
(40kW) |
(32.5kW) |
(32.5kW) |
(Low: 29kW/High: 35kW) |
| FUEL |
Kerosene, #1 Diesel |
Kerosene, #1 Diesel |
Kerosene, #1 Diesel |
Kerosene, #1 Diesel |
| TANK CAPACITY |
57LITERS |
35LITERS |
9.2 gallons |
15 gallons |
| POWER SOURCE |
230V/50Hz 120V/60Hz |
230V/50Hz |
120V/60Hz |
120V/60Hz |
| POWER CONSUMPTION |
65W |
60W |
80W |
120W |
| CONTROL SYSTEM |
5SEC. PREPURGE
|
5SEC. PREPURGE
|
5SEC. PREPURGE
|
5SEC. PREPURGE
|
|
180SEC. POSTPURGE |
180SEC. POSTPURGE |
180SEC. POSTPURGE |
180SEC. POSTPURGE |
| SAFTY DEVICE |
PHOTOCELL FLAME MONITOR
1.6A FUSE |
PHOTOCELL FLAME
MONITOR
1.6A FUSE |
PHOTOCELL FLAME
MONITOR
3A FUSE |
PHOTOCELL FLAME
MONITOR
3A FUSE |
| FUEL CONSUMPTION |
3.8 l/h |
3.21 l/h |
0.85gal/h |
High: 0.9gal/h
Low: 0.75gal/h |
EXTERNAL DIMENSION (HXWXD) |
925X660X955(mm) |
810X655X695(mm) |
36.2X27.9X27.4(in) |
40.2X28.0X27.4(in) |
| DRY WEIGHT |
53kg |
38kg |
83.8lbs |
92.6lbs |
| ACCESSORY |
N/A |
THERMOSTAT
TERMINALS |
THERMOSTAT
TERMINALS |
THERMOSTAT TERMINALS
FUEL PRE-HEATER |
| Specifications are subject to change without notice. |
|
|